Professional Equipment · Authorized Reseller

Diode Laser
Hair Removal Machine

Four-wavelength platform — 755 nm · 808 nm · 940 nm · 1064 nm — delivering 1800 W of peak power with sapphire contact cooling. Designed for professional hair removal across all Fitzpatrick skin types.

755 nm808 nm940 nm1064 nm1800 WCE marking (EU), UK regulatory status, FDA clearance, and Health Canada licensing apply only where documented for the exact device model and intended use.
Professional 4-wavelength diode laser hair removal machine — front view showing touchscreen and handpiece

Holiday Sale Bundle — machine purchase includes complimentary Laser Technician Course enrolment (valued at C$2,495 + HST)

View Training Details →

Four Wavelengths. One Platform.

Each wavelength targets the hair follicle differently. Using all three allows the operator to customise treatment for each client's skin tone and hair characteristics.

755 nm
Alexandrite Range
Fitzpatrick I–III

Targets melanin in fine, light hair with high absorption. Ideal for lighter skin tones and finer hair.

808 nm
Standard Diode
Fitzpatrick I–IV

The gold-standard diode wavelength — deep follicle penetration with balanced melanin absorption.

940 nm
Enhanced Diode
Fitzpatrick II–V

Bridges the 808nm and 1064nm ranges. Targets the dermal papilla with strong water absorption for effective follicle destruction.

1064 nm
Nd:YAG Range
Fitzpatrick IV–VI

Lower melanin absorption allows safe treatment of darker skin tones and tanned skin.

Machine Overview

Diode laser machine front view — touchscreen control panel, handpiece holder, and emergency stop button

Front View

15.6″ colour touchscreen · emergency stop · power button · handpiece holder

Diode laser machine rear view — ventilation, power input, water connections, and cable management

Rear View

Dual ventilation fans · power input · water circuit connections · cable routing

Interchangeable Handpiece Heads

Multiple treatment heads allow the operator to select the appropriate spot size for each treatment area. Heads are user-replaceable without tools.

Large diode laser handpiece side view

Large Body Handpiece

Large rectangular spot for fast coverage on legs, back, chest, and abdomen.

Standard diode laser handpiece pair showing front and side

Standard Handpiece

Versatile rectangular spot for arms, underarms, bikini line, and general body areas.

Precision diode laser handpiece showing interchangeable head swap

Precision Handpiece

Smaller spot for facial areas, upper lip, chin, sideburns, and detailed work.

All diode laser handpiece heads displayed together — large body, standard, and precision treatment heads

Complete Handpiece Head Set

All treatment heads are included with the machine. Each head is designed for a specific treatment area and spot size, allowing the operator to switch between large-area coverage and precision work without changing the handpiece body.

Heads are user-replaceable. Refer to the user manual for the correct removal and reattachment procedure.

Built-in Analysis System

Skin & Hair Analyser

Before every treatment the machine guides the operator through a two-part client assessment — skin tone and hair thickness — so the system can recommend the most effective wavelength, fluence, and pulse duration for that individual client.

1

Skin Tone Selection

The operator selects the client's Fitzpatrick skin type (I–VI) from the touchscreen. The system uses this to set safe energy limits and recommend the most appropriate wavelength — 755 nm for lighter tones, 808 nm for mid-range, and 1064 nm for darker skin.

Type IVery fair · always burns, never tans
755 nm
Type IIFair · usually burns, sometimes tans
755 nm
Type IIIMedium · sometimes burns, always tans
808 nm
Type IVOlive · rarely burns, always tans
808 nm
Type VBrown · very rarely burns
1064 nm
Type VIDark · never burns
1064 nm

940 nm is available as a supplementary wavelength across all skin types at the operator's discretion.

2

Hair Thickness Selection

Hair thickness directly affects how much energy is needed to reach and disable the follicle. The operator selects from three thickness categories. Finer hair requires lower fluence; coarser hair requires higher fluence and longer pulse duration to ensure full follicle absorption.

─

Fine

Vellus · facial peach fuzz · light body hair

Short pulse · lower fluence
━

Medium

Standard body hair · underarms · bikini

Mid pulse · standard fluence
▬

Coarse

Dense body hair · legs · back · chest

Long pulse · higher fluence

Combined Assessment = Personalised Parameters

Once skin tone, hair thickness, and hair colour are entered, the machine uses these three inputs to suggest treatment settings for the client profile. The operator must review the suggested settings and may adjust them in Professional Mode, according to the manufacturer’s instructions and individual assessment.

15.6″ Touchscreen Interface

The built-in touchscreen guides the operator through client setup, skin type selection, and parameter configuration. Three treatment modes allow protocols to be tailored to each client.

Diode laser touchscreen showing client skin type selector — Fitzpatrick I through VI with body area selection for woman or man

Client Skin Type Setup

Operator selects client gender and Fitzpatrick skin type (I–VI) before treatment. The system adjusts recommended parameters accordingly.

Diode laser touchscreen showing handpiece selection screen with 1800W and 13.5×38.5mm spot size

Handpiece Selection

Select the active handpiece head. The screen confirms the spot size (13.5×38.5mm shown) and power output (1800W) before the session begins.

Diode laser Normal mode touchscreen — frequency, fluence, and three-level refrigeration controls

Normal Mode

Standard single-pulse delivery. Operator sets frequency (Hz), fluence (J/cm²), and refrigeration level (1–3). Suited to first-time clients and sensitive areas.

Diode laser Fast mode touchscreen — parameter setting with five skin tone levels and shot counter

Fast Mode (SHR)

Super Hair Removal — rapid in-motion delivery across five energy levels (I–V). Ideal for large body areas. Shot counter tracks delivery in real time.

Diode laser Professional mode touchscreen — pulse duration up to 999ms, frequency, fluence, refrigeration, and parameter save

Professional Mode

Full manual control — pulse duration adjustable up to 999ms, plus frequency, fluence, and refrigeration. Save custom parameter presets for repeat clients.

Sapphire Contact Tip

The sapphire crystal tip maintains contact with the skin at 0–5 °C throughout treatment, protecting the epidermis while delivering laser energy to the follicle.

Diode laser handpiece tip — front view showing sapphire contact window

Front View

Diode laser handpiece tip — side profile showing cooling contact surface

Side Profile

Diode laser handpiece tip — 3/4 angle view showing full head assembly

3/4 View

Built-in CRM system touchscreen showing client management interface on the diode laser machine

Built-in Client Management System

The on-device CRM stores each client's treatment history, preferred parameters, skin type, and session notes — all accessible directly from the touchscreen without a separate device or software subscription.

  • ·Store unlimited client profiles
  • ·Save and recall custom parameter presets per client
  • ·Track session count and treatment history
  • ·No internet connection required

Technical Specifications

Wavelengths755 nm · 808 nm · 940 nm · 1064 nm
Max Power Output1800 W
Pulse Duration5 – 400 ms
Fluence Range1 – 120 J/cm²
Frequency1 – 10 Hz
Spot SizeInterchangeable handpiece heads
Cooling SystemSapphire contact cooling + internal water circulation
Contact Cooling Temp0 – 5 °C
Display15.6″ colour touchscreen
Treatment ModesNormal · HR (Hair Removal) · SHR (Super Hair Removal)
Power Supply220 V / 50 Hz
DimensionsTower unit on 4-wheel mobile base

Specifications are provided for reference. Confirm current specifications with G21 at time of purchase.

Free Laser Technician Training Included

Every machine purchase includes complimentary enrolment in G21's Laser Technician Course — a comprehensive program covering laser physics, safety protocols, skin assessment, treatment parameters, and hands-on practice.

Frequently Asked Questions

Purchaser & Operator Responsibility Notice

This device is intended for use by trained professionals. Purchasers and operators are solely responsible for verifying their qualifications, scope of practice, applicable provincial and local regulatory requirements, and insurance coverage before purchasing or operating this equipment.

Completion of a training course does not independently authorize practice. Regulatory requirements vary by province and municipality. G21 Aesthetics Academy is an authorized reseller and does not provide legal or regulatory advice.

Regulatory documentation (CE marking, conformity declarations) is available on request. Contact G21 at 289-689-3401 or via the enquiry form below.

Enquire About This Machine

Contact G21 to discuss pricing, availability, financing options, and the included training bundle.

289-689-3401